SIMDUE

FusionFrame

What FusionFrame calculates

Steel, timber and masonry to Eurocode with the Danish national annex – from model and loads to a report where every check is shown with formula and clause reference.

Calculations

Coverage is derived directly from the calculation core – this is what FusionFrame delivers today.

AreaCoverage
Steel (EN 1993-1-1)Section classification, tension, compression, shear, bending and combined checks (6.2.x), column buckling (6.3.1), lateral-torsional buckling (6.3.2) and combined bending and compression (6.3.3). Grades S235, S275, S355 and S460 per product standard. Profiles: HE, IPE, INP, UNP, UPE and cold-formed / hot-finished hollow sections (RHS/SHS).
Steel – fire (EN 1993-1-2)Critical steel temperature for sections, column buckling and lateral-torsional buckling.
Timber (EN 1995-1-1)Solid timber (C14–C50, D18–D70) and glulam (GL 24h–32h, GL 24c–32c) in rectangular sections. Tension, compression, bending, shear, combined checks, column and beam stability, and deflection limits.
Timber – fire (EN 1995-1-2)Reduced cross-section (charring) for 1–4 exposed sides.
Masonry (EN 1996-1-1:2022, DS/INF 167:2021)Masonry walls as fields with vertically loaded strip, concentrated load, in-plane and out-of-plane shear, lateral load and cavity walls with ties. Units: clay brick, calcium silicate, lightweight concrete and aerated concrete.
Structural modelPlanar 2D frames with beams and columns – quick to build, easy to follow and easy to document. Supports (fixed, pinned, roller), hinges at member ends, eccentric connections and automatic self-weight. Linear-elastic analysis.
LoadsDead, live (categories), snow and wind loads as point, line and moment loads. Wind load module per EN 1991-1-4 with the Danish NA for buildings with flat, monopitch, duopitch and hipped roofs.
Load combinations (EN 1990)ULS (6.10a/6.10b per DK NA), SLS (characteristic, frequent, quasi-permanent) and accidental/fire. Consequence class CC1–CC3 (K_FI 0.9 / 1.0 / 1.1) and ψ factors from the selected national annex.
ServiceabilityDeflection limits per member and vibration check per EN 1990 DK NA table A1.4 (steel and timber).
National annexdk-na-2024 (Danish NA 2024) by default. EN recommended values without a national annex can be selected in settings.
ReportEditable .docx with structural overview, load cases, load combinations, member forces, section properties and utilisation per check with clause reference. Company logo and branding.

Focus and scope

Updated 2026-10

FusionFrame is built for the structures consulting engineers document every day – and makes them fast, transparent and easy to check.

  • Planar 2D frames: the format load-bearing structures are documented and checked in. Quick to model, easy to follow and ready to hand over – with masonry walls designed as separate wall fields.
  • Linear-elastic first-order frame analysis with stability (column buckling, lateral-torsional buckling) verified using the code formulas and buckling lengths – the method a checking engineer expects to follow.
  • Natural frequencies are calculated and used for the vibration check per the Danish NA.
  • Fire: critical steel temperature and reduced timber cross-section (charring) per EN 1993-1-2 and EN 1995-1-2.
  • Wind loads are calculated for buildings with flat, monopitch, duopitch and hipped roofs. Snow loads are entered directly as load values.
  • Timber: solid timber and glulam in rectangular sections.
  • Outside FusionFrame’s focus today: concrete structures (EN 1992), connection design, dynamic/seismic response analysis, foundations and geotechnics, and LVL, plywood and OSB.
  • SIMDUE is a calculation tool, not advice: the responsible engineer owns model choices, input and the assessment of results.

Try it yourself in an afternoon

14-day trial without a payment card. Your data is kept if you do not continue.